[Header]	
Customer Name	ILLUMINA, INC.
Product Type	15034056
Date Manufactured	25/04/2013
Lot	WO0000109329773
DesignStudio ID	26573
Target Plexity	28
	
[Probes]
Gene Name	Transcript ID	Assay ID	Left Exon	Right Exon	Species	Build ID	Chromosome	Start Position	End Position	ULSO Sequence	ULSO Genomic Hits	DLSO Sequence	DLSO Genomic Hits	Probe Strand	Designer	Design Score	SNP Masking	Labels
CYP3A4	NM_017460	6828746	6	5	Homo sapiens	hg19	chr7	99367420	99366099	AGAGACAGGCAAGCCTGTCACCTTGAAA	3	CGTCTTTGGGGCCTACAGCATGGATGT	4	MINUS	ILLUMINA	1.828	false	FromReportXYZ;FromStudyXYZ
CYP24A1	NM_000782	6728583	11	10	Homo sapiens	hg19	chr20	52773735	52771272	GCGTTTTGCCAGCGATAATACGC	1	GGTGGTATTTGCTAACATCATATCCAA	1	MINUS	ILLUMINA	1.602	false	FromStudyXYZ
CYP2J2	NM_000775	6861661	7	6	Homo sapiens	hg19	chr1	60370573	60366748	TACCACTTTGGCTGGGTACCACCT	2	ACCATGATCCTGACCAATTTGACGG	1	MINUS	ILLUMINA	1.627	false	
CYP2C19	NM_000769	6630338	4	5	Homo sapiens	hg19	chr10	96541724	96580282	TATTGATTGCTTCCTGATCAAAATGGAG	4	GCAAAACCAACAGTCTGAATTCACT	2	PLUS	ILLUMINA	1.839	false	
CYP7A1	NM_000780	6631423	3	2	Homo sapiens	hg19	chr8	59409197	59407156	CCAGCGACTTTCTGGAGTTTATTTCAA	1	ATGAAAGCAGCTACTGAAGAAGTGAAA	1	MINUS	ILLUMINA	1.986	false	
CYP1A1	NM_000499	6731607	6	5	Homo sapiens	hg19	chr15	75013340	75013073	CTTTGTAAACCAGTGGCAGATCAACC	2	CATCTGAGTTCCTACCTGAACGGTTT	1	MINUS	ILLUMINA	1.937	false	
CYP11A1	NM_001099773	6664406	4	3	Homo sapiens	hg19	chr15	74636166	74635444	GACCATGTGGCTGCATGGGACGTGATTTT	1	ACACCCAGAACTTCTACTGGGAATTG	1	MINUS	ILLUMINA	1.786	false	
CYP1A2	NM_000761	6689130	5	6	Homo sapiens	hg19	chr15	75045583	75047158	GTAAACCAGTGGCAGGTCAACCAT	3	GAGCTGTGGGAGGACCCCTCTGAGTT	1	PLUS	ILLUMINA	1.592	false	
CYP4X1	NM_178033	6721323	10	11	Homo sapiens	hg19	chr1	47515144	47515708	CTATGCCTACTTACCATTCTCAGCTGG	3	GGCAGGAGTTTGCCATGATTGAGTTA	1	PLUS	ILLUMINA	1.958	false	
CYP27A1	NM_000784	6692060	2	3	Homo sapiens	hg19	chr2	219677112	219677310	TGGCTCAACTCTTCTACTACTTTGCC	1	CCTGTTCGAGAAACGCATTGGCT	1	PLUS	ILLUMINA	1.59	false	
CYP51A1	NM_001146152	6656978	6	5	Homo sapiens	hg19	chr7	91753082	91752588	GACATTCTCCAAACTTTACTAGATGCTAC	4	GACTGATGATGAAGTAGCAGGGATGCT	3	MINUS	ILLUMINA	1.868	false	
CYP2B6	NM_000767	6694504	7	8	Homo sapiens	hg19	chr19	41518686	41522578	GAAAAAGACTGAAGCTTTTATCCCCTTC	2	AGCGGATTTGTCTTGGTGAAGGCAT	2	PLUS	ILLUMINA	1.845	false	
CYP27B1	NM_000785	6706113	7	6	Homo sapiens	hg19	chr12	58157913	58157554	ATTCATGTGGGTGACTATATTATCCCC	1	TGTGTCACTATGCCACTTCAAGGGA	1	MINUS	ILLUMINA	1.878	false	
CYP19A1	NM_031226	6667814	10	9	Homo sapiens	hg19	chr15	51504553	51503224	ACCCAATGAATTTACTCTTGAAAATTTTGC	1	TTCCTTATAGGTACTTTCAGCCATTTGGC	1	MINUS	ILLUMINA	1.618	false	
CYP2C9	NM_000771	6770766	0	1	Homo sapiens	hg19	chr10	96698573	96701640	TAGGTATTAAGGACATCAGCAAATCCT	5	TCTCAAAGGTCTATGGCCCTGTGTT	3	PLUS	ILLUMINA	1.867	false	
CYP2C8	NM_001198855	6694627	5	4	Homo sapiens	hg19	chr10	96824591	96818225	AAAACTTCAGGATTCTGAACTCCCCATG	2	TACTCATTGATTGTTTCCCAGGAAC	2	MINUS	ILLUMINA	1.853	false	
CYP4F12	NM_023944	6801622	8	9	Homo sapiens	hg19	chr19	15795975	15806787	TCTGAAGGACCGCGATCCTAAAGAGAT	7	TGCCCTTCCTGACCATGTGCGTGAA	8	PLUS	ILLUMINA	1.793	false	
CYP4F8	NM_007253	6848640	11	12	Homo sapiens	hg19	chr19	15739621	15740025	TATGGCTTTTATTCCTTTCTCGGCGG	5	AACTGCATCGGGCAGAAGTTCG	9	PLUS	ILLUMINA	1.445	false	
CYP4A11	NM_000778	6720477	11	10	Homo sapiens	hg19	chr1	47398463	47395940	ACGCTTTCCTGCCCTTCTCAGGAGGAT	2	TGCCATGAACGAGCTGAAGGTG	8	MINUS	ILLUMINA	1.375	false	
CYP7B1	NM_004820	6651260	5	4	Homo sapiens	hg19	chr8	65517273	65509447	TACATGGTGACCCTGAAATCTTTGAAGC	1	TGATCGTTTTATAGAAGATGGTAAGAAGA	1	MINUS	ILLUMINA	1.808	false	
CYP27C1	NM_001001665	6808007	7	6	Homo sapiens	hg19	chr2	127950704	127944924	TTGCAGAACTGGAGATTCACCTCGT	1	TTGAGATCAAAACATCTTCTCAGACCA	2	MINUS	ILLUMINA	1.869	false	
CYP4Z1	NM_178134	6855383	10	11	Homo sapiens	hg19	chr1	47582372	47583473	CTATGCCTTCATACCATTCTCAGCTGG	3	GGCAGCATTTTGCCATAATTGAGTG	3	PLUS	ILLUMINA	1.883	false	
CYP4F3	NM_001199209	6750182	8	9	Homo sapiens	hg19	chr19	15763730	15769115	TCTGAAGGACCGTGAGCCTAAAGAGAT	8	TGCCCTTCCTGACCATGTGCATTAA	8	PLUS	ILLUMINA	1.865	false	
CYP2R1	NM_024514	6730201	2	1	Homo sapiens	hg19	chr11	14907356	14902275	CCTTCCTTTATTCATGAAGATGACAAAA	1	GATATGGCCGAGGATGGGTTGATCA	1	MINUS	ILLUMINA	1.784	false	
CYP4F2	NM_001082	6706390	12	11	Homo sapiens	hg19	chr19	15990188	15989718	TCTGGCTTTTATTCCCTTCTCGGCA	8	ATCGGGCAGACGTTCGCGATGG	4	MINUS	ILLUMINA	1.311	false	
CYP3A43	NM_057095	6774452	0	1	Homo sapiens	hg19	chr7	99425771	99434106	ATGGGTTCTTGTGGCTACCAGCCT	1	TGGGACCCATTCACATAAACTTTTTAAG	2	PLUS	ILLUMINA	1.689	false	
PTGIS	NM_000961	6696844	9	8	Homo sapiens	hg19	chr20	48127597	48124558	GGGGAGGAGTTATGCGGTCAACAGCAT	1	TGGTGCACTTGGACTTGGAGCTGATCA	1	MINUS	ILLUMINA	1.844	false	
CYP26B1	NM_019885	6792537	2	1	Homo sapiens	hg19	chr2	72371150	72362508	TCCATTGGCGACATCCACCGCAACAA	1	TCTTCAGCCACGAGGCCCTGGAGAGTTA	1	MINUS	ILLUMINA	1.738	false	
[Targets]
Gene Name	Transcript ID	Assay ID	Assay Position	Validated	Left Exon	Right Exon	Probe Strand	Target Sequence
CYP3A4	NM_017460	6828746	NA	false	6	5	MINUS	ACATCCATGCTGTAGGCCCCAAAGACGTCTTTCAAGGTGACAGGCTTGCCTGTCTCT
CYP24A1	NM_000782	6728583	THREE_PRIME	false	11	10	MINUS	TTGGATATGATGTTAGCAAATACCACCATCTGAGGCGTATTATCGCTGGCAAAACGC
CYP2J2	NM_000775	6861661	NA	false	7	6	MINUS	CCGTCAAATTGGTCAGGATCATGGTACCCTTGGGCAGGTGGTACCCAGCCAAAGTGGTA
CYP2C19	NM_000769	6630338	CENTER	false	4	5	PLUS	AGTGAATTCAGACTGTTGGTTTTGCTTTTCCTTCTCCATTTTGATCAGGAAGCAATCAATA
CYP7A1	NM_000780	6631423	CENTER	false	3	2	MINUS	TTTCACTTCTTCAGTAGCTGCTTTCATTGCTTCTGGGTTCCTAATCATTTGAAATAAACTCCAGAAAGTCGCTGG
CYP1A1	NM_000499	6731607	THREE_PRIME	false	6	5	MINUS	AAACCGTTCAGGTAGGAACTCAGATGGGTTGACCCATAGCTTCTGGTCATGGTTGATCTGCCACTGGTTTACAAAG
CYP11A1	NM_001099773	6664406	NA	false	4	3	MINUS	CAATTCCCAGTAGAAGTTCTGGGTGTATATGTCAGCTTTACTGAAAATCACGTCCCATGCAGCCACATGGTC
CYP1A2	NM_000761	6689130	THREE_PRIME	false	5	6	PLUS	AACTCAGAGGGGTCCTCCCACAGCTCTGGGTCATGGTTGACCTGCCACTGGTTTAC
CYP4X1	NM_178033	6721323	THREE_PRIME	false	10	11	PLUS	TAACTCAATCATGGCAAACTCCTGCCCAATGCAGTTCCTTGATCCAGCTGAGAATGGTAAGTAGGCATAG
CYP27A1	NM_000784	6692060	CENTER	false	2	3	PLUS	AGCCAATGCGTTTCTCGAACAGGATGTAGCAAATAGCTTCCAAGGCAAAGTAGTAGAAGAGTTGAGCCA
CYP51A1	NM_001146152	6656978	NA	false	6	5	MINUS	AGCATCCCTGCTACTTCATCATCAGTCAAAGGACGCCCATCCTTGTATGTAGCATCTAGTAAAGTTTGGAGAATGTC
CYP2B6	NM_000767	6694504	THREE_PRIME	false	7	8	PLUS	ATGCCTTCACCAAGACAAATCCGCTTCCCTAAGGAGAAGGGGATAAAAGCTTCAGTCTTTTTC
CYP27B1	NM_000785	6706113	CENTER	false	7	6	MINUS	TCCCTTGAAGTGGCATAGTGACACAGAGTGACCAGCGTATTTTTGGGGATAATATAGTCACCCACATGAAT
CYP19A1	NM_031226	6667814	THREE_PRIME	false	10	9	MINUS	GCCAAATGGCTGAAAGTACCTATAAGGAACATTCTTTGCAAAATTTTCAAGAGTAAATTCATTGGGT
CYP2C9	NM_000771	6770766	FIVE_PRIME	false	0	1	PLUS	AACACAGGGCCATAGACCTTTGAGAGATTGGTTAAGGATTTGCTGATGTCCTTAATACCTA
CYP2C8	NM_001198855	6694627	NA	false	5	4	MINUS	GTTCCTGGGAAACAATCAATGAGTAGAGGGAAATTATTGCAGACCTGGATCCATGGGGAGTTCAGAATCCTGAAGTTTT
CYP4F12	NM_023944	6801622	CENTER	false	8	9	PLUS	TTCACGCACATGGTCAGGAAGGGCAGCTGGGCCAGGTCGTCCCATTCAATCTCTTTAGGATCGCGGTCCTTCAGA
CYP4F8	NM_007253	6848640	THREE_PRIME	false	11	12	PLUS	CGAACTTCTGCCCGATGCAGTTCCTGGGCCCCGCCGAGAAAGGAATAAAAGCCATA
CYP4A11	NM_000778	6720477	THREE_PRIME	false	11	10	MINUS	CACCTTCAGCTCGTTCATGGCAAATTGTTTCCCGATGCAGTTCCTTGATCCTCCTGAGAAGGGCAGGAAAGCGT
CYP7B1	NM_004820	6651260	THREE_PRIME	false	5	4	MINUS	TCTTCTTACCATCTTCTATAAAACGATCATATCTAAACTCCTCTGGAGCTTCAAAGATTTCAGGGTCACCATGTA
CYP27C1	NM_001001665	6808007	THREE_PRIME	false	7	6	MINUS	TGGTCTGAGAAGATGTTTTGATCTCAAAATGTTGAAGCAACTGGATCACGACGAGGTGAATCTCCAGTTCTGCAA
CYP4Z1	NM_178134	6855383	THREE_PRIME	false	10	11	PLUS	CACTCAATTATGGCAAAATGCTGCCCAATGCAGTTCCTTAATCCAGCTGAGAATGGTATGAAGGCATAG
CYP4F3	NM_001199209	6750182	CENTER	false	8	9	PLUS	TTAATGCACATGGTCAGGAAGGGCAGCTGGGCCAGGTCGTCCCATTCAATCTCTTTAGGCTCACGGTCCTTCAGA
CYP2R1	NM_024514	6730201	CENTER	false	2	1	MINUS	TGATCAACCCATCCTCGGCCATATCTGGAATTGAGTAAGCCTCCCATTTTTGTCATCTTCATGAATAAAGGAAGG
CYP4F2	NM_001082	6706390	THREE_PRIME	false	12	11	MINUS	CCATCGCGAACGTCTGCCCGATGCAGTTCCTGGGCCCTGCCGAGAAGGGAATAAAAGCCAGA
CYP3A43	NM_057095	6774452	FIVE_PRIME	false	0	1	PLUS	CTTAAAAAGTTTATGTGAATGGGTCCCATAAATATAGAGGAGTACCAGGCTGGTAGCCACAAGAACCCAT
PTGIS	NM_000961	6696844	THREE_PRIME	false	9	8	MINUS	TGATCAGCTCCAAGTCCAAGTGCACCAGCACAAGGAACACAAATTGTTTGATGCTGTTGACCGCATAACTCCTCCCC
CYP26B1	NM_019885	6792537	FIVE_PRIME	false	2	1	MINUS	TAACTCTCCAGGGCCTCGTGGCTGAAGATCTTGGAGAAGACCTTGCGCTTGTTGCGGTGGATGTCGCCAATGGA
